Product Identification
Product ID:J6V-633 RTS, SUNFIRE LOW VOC HARDENER, (SUPDAT)
MSDS Date:07/13/1995
FSC:8010
NIIN:00N067123
Kit Part:Y
MSDS Number: CBWNL
Responsible Party
CLEVELAND, OH 44115
US
Emergency Phone: 216-566-2917
Info Phone: 216-566-2902
Cage: 54636
Contractor
Telephone: 800-251-2486/216-566-2242
Cage: 54636
Ingredients
2-PENTANONE, 4-METHYL-; (METHYL ISOBUTYL KETONE) (SARA 313)
CAS: 108-10-1
RTECS: SA9275000
Fraction By Weight: 8%
OSHA PEL 100 PPM
ACGIH TLV: 50 PPM; 75 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
2.14
CAS: 110-43-0
RTECS: MJ5075000
Fraction By Weight: 7%
OSHA PEL 100 PPM
ACGIH TLV: 50 PPM
ACETIC ACID, BUTYL ESTER; (N-BUTYL ACETATE) (CERCLA) VP
CAS: 123-86-4
RTECS: AF7350000
Fraction By Weight: 11%
OSHA PEL 150 PPM
ACGIH TLV: 150 PPM; 200 STEL
EPA Report Quantity: 5000 LBS
DOT Report Quantity: 5000 LBS
ACETIC ACID, 2-METHOXY-1-METHYLETHYL ESTER;
CAS: 108-65-6
RTECS: AI8925000
Fraction By Weight: 20%
OSHA PEL N/K
ACGIH TLV: N/K
0
CAS: 3779-63-3
Fraction By Weight: 18%
OSHA PEL N/K
ACGIH TLV: N/K
0
CAS: 53880-05-0
Fraction By Weight: 5%
OSHA PEL 0.005 PPM (0.02 C)
ACGIH TLV: 0.005 PPM, S
TITANIUM OXIDE; (TITANIUM DIOXIDE)
CAS: 13463-67-7
RTECS: XR2275000
Fraction By Weight: 5-10%
OSHA PEL 15 MG/M3 TDUST
ACGIH TLV: 10 MG/M3 TDUST
3.17 LB; 380 G (THEORETICAL)
RTECS: 9999999VO
OSHA PEL N/K
ACGIH TLV: N/K
BURSTING OF CLOSED CONTAINERS.
RTECS: 9999999ZZ
RPTD EXPOS. RATS EXPOS TO TITANIUM DIOXIDE
RTECS: 9999999ZZ
SUCH EXPOS LEVELS ARE NOT ATTAINABLE IN WORKPLACE.
RTECS: 9999999ZZ
BRAIN & NERVOUS SYS DMG. INTENTIONAL MISUSE BY
RTECS: 9999999ZZ
CONTAINS CHEM(S) KNOWN TO STATE OF CA TO CAUSE
RTECS: 9999999ZZ
& ADD MORE AMMONIA. COVER LOOSELY. WASH SPILL
RTECS: 9999999ZZ
FLAMES, PILOT LIGHTS & HEATERS. TURN OFF
RTECS: 9999999ZZ
OF IGNIT. CONSULT NFPA CODE. USE APPRVD BONDING &
RTECS: 9999999ZZ
TRANSFER ONLY TO APPRVD CNTNRS W/COMPLETE & APPROP
RTECS: 9999999ZZ
PROBS OR IF THEY HAVE EVER HAD RXN TO
RTECS: 9999999ZZ
MIST. AVOID CNTCT W/SKIN & EYES. WASH HANDS AFTER
RTECS: 9999999ZZ
PARTICULATES WHICH MAY BE PRESENT AT HAZ LEVELS
RTECS: 9999999ZZ
SPECIFIC DUSTS ARE LISTED, APPLIC LIMS FOR NUISANCE
RTECS: 9999999ZZ
MG/M3 (TDUST), 5 MG/M3 (RESPIRABLE FRACTION).
RTECS: 9999999ZZ
FOR WHOLE TIME OF SPRAYING & UNTIL ALL VAPS &
RTECS: 9999999ZZ
WHERE PROD IS BEING USED UNLESS EQUIPPED W/SAME
RTECS: 9999999ZZ
WEAR DUST/MIST RESP APPRVD BY NIOSH/MSHA FOR DUST
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EXPOS MAY BE BY INHAL &/OR SKIN/EYE
CNTCT DEPENDING ON CNDTNS OF USE. TO MIN EXPOS, FOLLOW RECOMS FOR
PROPER USE, VENT & PERSONAL PROT EQUIP. ACUTE: IRRIT OF EYES, SKIN
& RESP SYS. MAY CAUSE NERVOUS S YS DEPRESS. EXTREME OVEREXP MAY
RSLT INUNCON & POSS DEATH. HDCH, DIZZ, NAUS & LOSS OF COORDINATION
(EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:HLTH HAZ: ARE INDICATIONS OF EXCESS EXPOS TO
VAPS OR SPRAY MISTS. REDNESS & ITCH OR BURNING SENSATION MAY
INDICATE EYE/EXCESS SKIN EXPOS. CHRONIC: PRLNGD OVEREXP TO SOLV
INGREDS MAY CAUSE ADVERSE EFTS TO LIVER, URINARY & BLOOD FORMING
SYS.PERS SENSITIVE TO ISOCYANATES WILL EXPERIENCE INCRD ALLERGIC
RXN ON (ING 10)
Medical Cond Aggravated by Exposure:MAY CAUSE ALLERGIC RESPIRATORY
AND/OR SKIN REACTION IN SUSCEPTIBLE PERSONS OR SENSITIZATION. THIS
EFFECT MAY BE DELAYED SEVERAL HOURS AFTER EXPOSURE.
First Aid
First Aid:INHAL: IF ANY BREATHING PROBLEMS OCCUR DURING USE, LEAVE AREA
AND GET FRESH AIR. IF PROBLEMS REMAIN OR OCCUR LATER, IMMEDIATELY
GET MEDICAL ATTENTION. SKIN: WASH AFFECTED AREA THOROUGHLY WITH
SOAP AND WATER. REMOVE CONTAMINATED CLOTHING AND LAUNDER BEFORE
REUSE. EYES: FLUSH EYES WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINUTES. GET MEDICAL ATTENTION. INGEST: GET MEDICAL ATTENTION.
Fire Fighting
Flash Point Method:TCC
Flash Point:82.0F,27.8C
Lower Limits:0.9%
Upper Limits:13.1%
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:USE NIOSH/MSHA APPRVD SCBA & FULL PROT EQUIP.
WATER SPRAY MAY BE INEFTIVE. IF WATER IS USED, FOG NOZZS ARE PREF.
WATER MAY BE USED TO COOL CLSD (SUPDAT)
Unusual Fire/Explosion Hazard:KEEP CNTNRS TIGHTLY CLSD. ISOLATE FROM
HEAT, ELEC EQUIP, SPKS & OPEN FLAME. CLSD CNTNRS MAY EXPLODE WHEN
EXPOS TO EXTREME HEAT. APPLICATN TO HOT SURFS (SUDPAT)
Accidental Release
Spill Release Procedures:REMOVE ALL SOURCES OF IGNIT. VENT AREA. ALL
PERS IN ARREA SHOULD BE PROTECTED AS LISTED IN PROT INFO. COVER
SPILL W/ABSORB MATL. DEACTIVATE SPILLED MATL W/10% AMMONIUM
HYDROXIDE SOLN (HOUSEHOLD AMMONI A). AFTER 10 MIN, COLLECT IN OPEN
CNTNRS (ING 14)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:CONTENTS ARE FLAMM. KEEP AWAY FROM
HEAT, SPKS & OPEN FLAME. DURING USE & UNTIL ALL VAPS ARE GONE:KEEP
AREA VENT. DO NOT SMOKE. EXTING ALL (ING 15)
Other Precautions:PROD MUST BE MIXED W/OTHER COMPONENTS BEFORE USE.
BEFORE OPENING PACKAGES, READ & FOLLOW WARNING LABELS ON ALL
COMPONENTS. NO PERSON SHOULD USE PROD/BE IN AREA WHERE IT IS BEING
USED IF THEY HAVE CHRO NIC (LONG-TERM) LUNG/BRTHG (ING 18)
Exposure Controls
Respiratory Protection:WHERE OVERSPRAY IS PRESENT, NIOSH/MSHA APPRVD
POS PRESS AIR SUPPLIED RESP (TC19C) SHOULD BE WORN. IF UNAVAIL,
PROPERLY FITTED NIOSH/MSHA APPRVD ORG VAP/PARTICULATE RESP MAY BE
EFTIVE. FOLLOW RESP MFR' S DIRECTIONS FOR USE. WEAR RESP (ING 23)
Ventilation:LOC EXHST PREF. GEN EXHST ACCEPTABLE IF EXPOS MAINTAINED
BELOW APPLIC EXPOS LIMS. REFER TO OSHA STDS 1910.94, 107, 108.
Protective Gloves:IMPERVIOUS GLOVES .
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPROVED EMERGENCY EYE WASH & DELUGE
SHOWER . USE BARRIER CREAM ON EXPOSED SKIN.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
MFR'S TRADE NAME/PART NO: READY TO SPRAY 3:1 W/V6-V1123. FIRE FIGHT
PROC: CNTNRS TO PVNT PRESS BUILD-UP & POSS AUTOIGNIT/EXPLO WHEN
EXPOSED TO EXTREME HEAT. EXPLO HAZ: REQS SPEC PRECS. DURING EMER
CND TNS OVEREXP TO DECOMP PRODS MAY CAUSE HLTH HAZ. SYMPS MAY NOT
BE IMMED APPARENT. OBTAIN MED ATTN.
Chemical Properties
Boiling Pt:B.P. Text:>237F,>114C
Vapor Pres:SEE INGS
Vapor Density:HVR/AIR
Spec Gravity:1.06
Evaporation Rate & Reference:SLOWER THAN ETHER
Appearance and Odor:NONE SPECIFIED BY MANUFACTURER.
Percent Volatiles by Volume:44
Stability
Stability Indicator/Materials to Avoid:YES
CONTAM W/WATER, ALCOHOLS, AMINES & OTHER CMPDS WHICH REACT
W/ISOCYANATES MAY RSLT IN DANGEROUS PRESS IN & POSS (ING 9)
Stability Condition to Avoid:NONE KNOWN.
Hazardous Decomposition Products:BY FIRE: CARBON DIOXIDE, CARBON
MONOXIDE, OXIDES OF NITROGEN, POSSIBILITY OF HYDROGEN CYANIDE.
Disposal
Waste Disposal Methods:WASTE FROM PROD MAY BE HAZ AS DEFINED UNDER RCRA
40 CFR 261. WASTE MUST BE TESTED FOR IGNITABILITY TO DETERMINE
APPLIC EPA HAZ WASTE NUMBERS. INCIN IN APPRVD FACILITY. DO NOT
INCIN CLSD CNTNR. DISP OF I/A/W FED, STATE & LOC REGS REGARDING
POLLUTION.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.